Add to Cart
Product parameters | ||
Routine | Operating temperature | 0~50℃ |
Operating humidity | <95%RH (not dew) | |
Power supply | AC220V (±15%), 50Hz | |
Air supply | 0.4~0.8MPa (clean, dry) | |
Test medium | Compressed air or specified medium by customers | |
Net weight | 17Kg | |
Appearance | Dimension | 277mm*465mm*235mm |
Built in oil-water separator | ||
The screen display angle is adjustable (75 degrees and 90 degrees), which is suitable for switching angle display indifferent environments | ||
Software | System | Android 7.12 system, more intelligent operation |
Languages | Chinese, English, Japanese, German, French, Russian | |
Unit | Pa,kPa,MPa,psi,bar,Mbar,mmHg | |
Storage | Historic records | lt can store 1 million records and export them to the computer through USB flash disk |
CPU | 1.4GHz | |
RAM | 2GB memory,16GB storage | |
Display | Touch screen | 10 inch multi-point color touch screen |
Interface skin | UI 3.0 | |
Hardware | USB interface | Software upgrade, export / import data and mouse input are available |
Communication interface | It can be connected with industrial computer, extended functions | |
Bar-code scanner | Support | |
Judge / alarm | Automatic judgment / light + sound alarm | |
Control I/O interface | lnput / output: start, stop, 8 groups of relay control functions | |
Ethernet / WiFi | Update the software online | |
HDMI | External display | |
Function /accuracy | Test method | Positive / Negative / Differential / Volume / Re-volume / Microscale |
Number of the test ports | 1/2/4 (No differential pressure for 2&4 channel) | |
Pressure regulation mode | Automatic adjustment | |
Pressure regulation accuracy | ±0.01%FS | |
Pressure repetition accuracy | 0.1%FS | |
Pressure range | -60kPa~1Mpa | |
Measurement resolution | 1 pa | |
Sensor selection range | -50kPa~700kPa / -50kPa~1MPa | |
Sensor accuracy | ±0.02%FS~0.05%FS | |
Number of programs | 1000 groups |
Advantages
0.02%FS PRECISION
Technical level of domestic first-line brands.
It is suitable for application scenarios with higher precision
requirements and more complex working conditions.
SCIENTIFIC DESIGNOF PRODUCT STRUCTURE
The valve terminal adopts integrated design. With USB mouse input,
large screen operation, built-in oil-water separator, realize safe operation and anti-interference.
AUTOMATIC PRESSURE REGULATION
Just input the target pressure value on the operation screen,
and the internal pressure regulating device of the tester will automatically
adjust to the target pressure value, the automatic pressure regulating accuracy is within ±200Pa.